Compare Equipment Go Back

DE33E0 (50 Hz) Generator Set
3612 Generator Set (Medium Speed)
C280-8 Generator Set (Medium Speed)
3616 Generator Set (Medium Speed)
3608 Generator Set (Medium Speed)
C280-6 Generator Set (Medium Speed)

Generator Set Specifications

Minimum Rating 33 kVA 4400 kVA 2200 ekW (60Hz), 2938 kVA (50Hz) 4700 kVA 2363 kVA 3150 ekW 1650 ekW (60Hz), 2200 kVA (50Hz)
Maximum Rating 33 kVA 4850 kVA 2420 ekW (60Hz), 3250 kVA (50Hz) 7520 kVA 3575 kVA 4000 ekW 1820 ekW (60Hz), 2425 kVA (50Hz)
Emissions/Fuel Strategy Non Regulated Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 Low Fuel Consumption Low Fuel Consumption Low Fuel, Tier 2 IMO Tier 2
Voltage 220 to 415 Volts - - - - 480 to 13800 Volts -
Frequency 50 Hz 50 Hz 50 / 60 Hz 50 Hz 50 Hz 60 Hz 50 / 60 Hz
Speed 1500 rpm 750 & 1000 rpm 900 / 1000 rpm 720 & 1000 rpm 750 & 1000 rpm 1800 rpm 900 / 1000 rpm
Duty Cycle Standby, Prime Prime, Continuous Prime, Continuous Standby, Prime, Continuous Standby, Prime, Continuous Standby, Mission Critical, Prime, Continuous Prime, Continuous
Standby Rating - - - - - 4000 (no fan)/3900/3620(no fan)/3500 ekW -
Prime Power Rating - - - - - 3600 (no fan)/3500/3300 (no fan)/3180 ekW -

Engine Specifications

Engine Model Cat® C3.3 3612 V-12,4-Stroke Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel C280-6, I-6,4-Stroke Water-Cooled Diesel
Bore 4.1 in 11 in 11 in 11 in 11 in 6.89 in 11 in
Stroke 5 in 11.8 in 11.8 in 11.8 in 11.8 in 8.66 in 11.8 in
Displacement 201.4 in³ 13524 in³ 9064 in³ 18032 in³ 9064 in³ 6456.31 in³ 111 in³
Compression Ratio 19.25:1 13:01 13:01 13:01 13:01 15.3:1 13:01
Aspiration Turbocharged TA TA TA TA Turbo Aftercooled TA
Fuel System Inline Direct unit injection Direct unit injection Direct unit injection Direct unit injection Common Rail Direct unit injection
Governor Type Mechanical Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) ADEM� A4 Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Maximum 60.6 in 404 in 404 in 404 in 404 in 331.1 in 404 in
Width - Maximum 44.1 in 99.62 in 99.62 in 99.62 in 99.62 in 128.5 in 99.62 in
Height - Maximum 53.6 in 156.6 in 156.6 in 156.6 in 156.6 in 150.7 in 156.6 in
Dry Weight - Genset (maximum) 1823 lb 112690 lb 91050 lb 141840 lb 91050 lb 66200 lb 74970 lb
Length - Minimum - - - - - 262.5 in -
Width - Minimum - - - - - 92 in -
Height - Minimum - - - - - 99.8 in -
Dry Weight - Genset (minimum) - - - - - 55100 lb -
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • C280-12 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C175-16 Generator Set Add
  • C175-16 Tier 4 Final Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Generator Set Add