Compare Equipment Go Back

C2.2 | DE18E3 50Hz EU IIIA EMISSIONS COMPLIANT
3606 Generator Set (Medium Speed)
C280-6 Generator Set (Medium Speed)
C280-8 Generator Set (Medium Speed)
C175-16 Tier 4 Final
3612 Generator Set (Medium Speed)
3616 Generator Set (Medium Speed)
C280-12 Generator Set (Medium Speed)

Generator Set Specifications

Minimum Rating 18 kVA 1775 kVA 1650 ekW (60Hz), 2200 kVA (50Hz) 2200 ekW (60Hz), 2938 kVA (50Hz) 2500 ekW 4400 kVA 4700 kVA 3300 ekW (60Hz), 4400 kVA (50Hz)
Maximum Rating 18 kVA 2688 kVA 1820 ekW (60Hz), 2425 kVA (50Hz) 2420 ekW (60Hz), 3250 kVA (50Hz) 3100 ekW 4850 kVA 7520 kVA 3640 ekW (60Hz), 4850 kVA (50Hz)
Emissions/Fuel Strategy R96/EUIIIa Equivalent Low Fuel Consumption IMO Tier 2 EPA Tier 4 Final, IMO Tier 2 U.S. EPA Certified Tier 4 Low Fuel Consumption Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2
Voltage 200 to 400 Volts - - - 480 to 13800 Volts - - -
Frequency 50 Hz 50 Hz 50 / 60 Hz 50 / 60 Hz 60 Hz 50 Hz 50 Hz 50 / 60 Hz
Duty Cycle Standby, Prime Continuous Prime, Continuous Prime, Continuous Standby, Mission Critical, Prime, Continuous Prime, Continuous Standby, Prime, Continuous Prime, Continuous
Speed - 750 & 1000 rpm 900 / 1000 rpm 900 / 1000 rpm 1800 rpm 750 & 1000 rpm 720 & 1000 rpm 900 / 1000 rpm
Standby Rating - - - - 3100(no fan)/3000 ekW - - -
Prime Power Rating - - - - 2825(no fan)/2725 ekW - - -

Engine Specifications

Aspiration Turbocharged TA TA TA Turbo Aftercooled TA TA TA
Engine Model - 3606 I-6, 4-Stroke Water-Cooled Diesel C280-6, I-6,4-Stroke Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel 3612 V-12,4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel
Bore - 11 in 11 in 11 in 6.89 in 11 in 11 in 11 in
Stroke - 11.8 in 11.8 in 11.8 in 8.66 in 11.8 in 11.8 in 11.8 in
Displacement - 6762 in³ 111 in³ 9064 in³ 5155.88 in³ 13524 in³ 18032 in³ 13524 in³
Compression Ratio - 13:01 13:01 13:01 16.7:1 13:01 13:01 13:01
Fuel System - Direct unit injection Direct unit injection Direct unit injection EUI Direct unit injection Direct unit injection Direct unit injection
Governor Type - Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) ADEM� A4 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Maximum - 404 in 404 in 404 in 320 in 404 in 404 in 404 in
Width - Maximum - 99.62 in 99.62 in 99.62 in 122.8 in 99.62 in 99.62 in 99.62 in
Height - Maximum - 156.6 in 156.6 in 156.6 in 142.3 in 156.6 in 156.6 in 156.6 in
Dry Weight - Genset (maximum) - 74970 lb 74970 lb 91050 lb 45114 lb 112690 lb 141840 lb 112690 lb
Length - Minimum - - - - 242.77 in - - -
Width - Minimum - - - - 82.7 in - - -
Height - Minimum - - - - 127.2 in - - -
Dry Weight - Genset (minimum) - - - - 42750 lb - - -
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C175-20 Add
  • 3516E Low Voltage Generator Set Add
  • C175-16 Generator Set Add
  • 3516E Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Generator Set Add