Compare Equipment Go Back

C32 | 1500 kVA 50Hz Generator Set
C280-8 Generator Set (Medium Speed)
C280-6 Generator Set (Medium Speed)
3616 Generator Set (Medium Speed)
3612 Generator Set (Medium Speed)
3608 Generator Set (Medium Speed)
C4.4 Generator Set
3612 Generator Set (Medium Speed)

Generator Set Specifications

Maximum Rating 1500 kVA 2420 ekW (60Hz), 3250 kVA (50Hz) 1820 ekW (60Hz), 2425 kVA (50Hz) 7520 kVA 4850 kVA 2660 ekW 110 kVA 4000 ekW
Minimum Rating 910 kVA 2200 ekW (60Hz), 2938 kVA (50Hz) 1650 ekW (60Hz), 2200 kVA (50Hz) 4700 kVA 4400 kVA 1830 ekW 50 kVA 3300 ekW
Emissions/Fuel Strategy Low Fuel, Low Emissions EPA Tier 4 Final, IMO Tier 2 IMO Tier 2 Low Fuel Consumption Low Fuel Consumption Low Fuel Consumption EU Stage II & R96/EUIIIa Low Fuel Consumption
Voltage 400 to 3300 Volts - - - - - 110 to 480 Volts -
Frequency 50 Hz 50 / 60 Hz 50 / 60 Hz 50 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Speed 1500 rpm 900 / 1000 rpm 900 / 1000 rpm 720 & 1000 rpm 750 & 1000 rpm 720 & 900 rpm 1500 rpm 720 & 900 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous Prime, Continuous Prime, Continuous Standby, Prime, Continuous Prime, Continuous Standby, Prime, Continuous Standby, Prime Prime, Continuous

Engine Specifications

Engine Model C32 TA, V-12, 4-Stroke Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel C280-6, I-6,4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel 3612 V-12,4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel Cat® C4.4 3612 V-12,4-Stroke Water-Cooled Diesel
Bore 5.71 in 11 in 11 in 11 in 11 in 11 in 4.1 in 11 in
Stroke 6.38 in 11.8 in 11.8 in 11.8 in 11.8 in 11.8 in 5 in 11.8 in
Displacement 1958.86 in³ 9064 in³ 111 in³ 18032 in³ 13524 in³ 9064 in³ 268.5 in³ 13524 in³
Compression Ratio 15.0:1 13:01 13:01 13:01 13:01 13:01 16.2:1, 17.25:1, 18.2:1 or 18.3:1 13:01
Aspiration Turbocharged, Air to Air Aftercooled TA TA TA TA TA Turbocharged TA
Fuel System MEUI Direct unit injection Direct unit injection Direct unit injection Direct unit injection Direct unit injection Direct Injection or Common Rail Direct unit injection
Governor Type Adem™A4 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Mechanical Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Minimum 164 in - - - - - - -
Length - Maximum 176.6 in 404 in 404 in 404 in 404 in 404 in 75.8 in 404 in
Width - Minimum 66.3 in - - - - - - -
Width - Maximum 87.8 in 99.62 in 99.62 in 99.62 in 99.62 in 99.62 in 44.1 in 99.62 in
Height - Minimum 85.1 in - - - - - - -
Height - Maximum 86.4 in 156.6 in 156.6 in 156.6 in 156.6 in 156.6 in 53.6 in 156.6 in
Dry Weight - Genset (minimum) 14700 lb - - - - - - -
Dry Weight - Genset (maximum) 17855 lb 91050 lb 74970 lb 141840 lb 112690 lb 91050 lb - 112690 lb
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • C280-12 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C175-20 Add
  • 3606 Generator Set (Medium Speed) Add
  • C175-16 Generator Set Add
  • C175-16 Tier 4 Final Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Generator Set Add