C32 | 1500 kVA 50Hz Generator Set
3606 Generator Set (Medium Speed)
3608 Generator Set (Medium Speed)
3612 Generator Set (Medium Speed)
3608 Generator Set (Medium Speed)
C175-16 Tier 4 Final
3516E Generator Set

Generator Set Specifications

Maximum Rating 1500 kVA 2688 kVA 2660 ekW 4000 ekW 3575 kVA 4000 ekW 3100 ekW 3500 kVA
Minimum Rating 910 kVA 1775 kVA 1830 ekW 3300 ekW 2363 kVA 3150 ekW 2500 ekW 3000 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions Low Fuel Consumption Low Fuel Consumption Low Fuel Consumption Low Fuel Consumption Low Fuel, Tier 2 U.S. EPA Certified Tier 4 Tier 2 Equivalent - 1800 rpm
Voltage 400 to 3300 Volts - - - - 480 to 13800 Volts 480 to 13800 Volts 380 to 11000 volts
Frequency 50 Hz 50 Hz 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz 50 Hz
Speed 1500 rpm 750 & 1000 rpm 720 & 900 rpm 720 & 900 rpm 750 & 1000 rpm 1800 rpm 1800 rpm 1800 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous Continuous Standby, Prime, Continuous Prime, Continuous Standby, Prime, Continuous Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime, Continuous Standby, Mission Critical
Standby Rating - - - - - 4000 (no fan)/3900/3620(no fan)/3500 ekW 3100(no fan)/3000 ekW -
Prime Power Rating - - - - - 3600 (no fan)/3500/3300 (no fan)/3180 ekW 2825(no fan)/2725 ekW -

Engine Specifications

Engine Model C32 TA, V-12, 4-Stroke Water-Cooled Diesel 3606 I-6, 4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel 3612 V-12,4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke Water-Cooled Diesel
Bore 5.71 in 11 in 11 in 11 in 11 in 6.89 in 6.89 in 6.69 in
Stroke 6.38 in 11.8 in 11.8 in 11.8 in 11.8 in 8.66 in 8.66 in 8.46 in
Displacement 1958.86 in³ 6762 in³ 9064 in³ 13524 in³ 9064 in³ 6456.31 in³ 5155.88 in³ 4765 in³
Compression Ratio 15.0:1 13:01 13:01 13:01 13:01 15.3:1 16.7:1 14.7:1
Aspiration Turbocharged, Air to Air Aftercooled TA TA TA TA Turbo Aftercooled Turbo Aftercooled ATAAC
Fuel System MEUI Direct unit injection Direct unit injection Direct unit injection Direct unit injection Common Rail EUI Electronic Unit Injection
Governor Type Adem™A4 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) ADEM� A4 ADEM� A4 Adem™5

Generator Set Dimensions

Length - Minimum 164 in - - - - 262.5 in 242.77 in 335.1 in
Length - Maximum 176.6 in 404 in 404 in 404 in 404 in 331.1 in 320 in 335.1 in
Width - Minimum 66.3 in - - - - 92 in 82.7 in 104 in
Width - Maximum 87.8 in 99.62 in 99.62 in 99.62 in 99.62 in 128.5 in 122.8 in 104 in
Height - Minimum 85.1 in - - - - 99.8 in 127.2 in 131.6 in
Height - Maximum 86.4 in 156.6 in 156.6 in 156.6 in 156.6 in 150.7 in 142.3 in 131.6 in
Dry Weight - Genset (minimum) 14700 lb - - - - 55100 lb 42750 lb 50706 lb
Dry Weight - Genset (maximum) 17855 lb 74970 lb 91050 lb 112690 lb 91050 lb 66200 lb 45114 lb 50706 lb
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • 3616 Generator Set (Medium Speed) Add
  • C280-12 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-16 Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Generator Set Add