Compare Equipment Go Back

DE110E2 (50 Hz) Generator Set
3616 Generator Set (Medium Speed)
3606 Generator Set (Medium Speed)
C280-8 Generator Set (Medium Speed)
3608 Generator Set (Medium Speed)

Generator Set Specifications

Minimum Rating 100.0 kVA 4700 kVA 1775 kVA 2200 ekW (60Hz), 2938 kVA (50Hz) 1830 ekW 3150 ekW
Maximum Rating 110.0 kVA 7520 kVA 2688 kVA 2420 ekW (60Hz), 3250 kVA (50Hz) 2660 ekW 4000 ekW
Emissions/Fuel Strategy EU Stage II R96 Low Fuel Consumption Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 Low Fuel Consumption Low Fuel, Tier 2
Voltage 220 to 415 Volts - - - - 480 to 13800 Volts
Frequency 50 Hz 50 Hz 50 Hz 50 / 60 Hz 60 Hz 60 Hz
Speed 1500 rpm 720 & 1000 rpm 750 & 1000 rpm 900 / 1000 rpm 720 & 900 rpm 1800 rpm
Duty Cycle Standby, Prime Standby, Prime, Continuous Continuous Prime, Continuous Standby, Prime, Continuous Standby, Mission Critical, Prime, Continuous
Standby Rating - - - - - 4000 (no fan)/3900/3620(no fan)/3500 ekW
Prime Power Rating - - - - - 3600 (no fan)/3500/3300 (no fan)/3180 ekW

Engine Specifications

Engine Model Cat® C4.4 3616 V-16, 4-Stroke Water-Cooled Diesel 3606 I-6, 4-Stroke Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel
Bore 4.1 in 11 in 11 in 11 in 11 in 6.89 in
Stroke 5 in 11.8 in 11.8 in 11.8 in 11.8 in 8.66 in
Displacement 201.4 in³ 18032 in³ 6762 in³ 9064 in³ 9064 in³ 6456.31 in³
Compression Ratio 18.3:1 13:01 13:01 13:01 13:01 15.3:1
Aspiration Turbocharged TA TA TA TA Turbo Aftercooled
Fuel System Inline Direct unit injection Direct unit injection Direct unit injection Direct unit injection Common Rail
Governor Type Electronic Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) ADEM� A4

Generator Set Dimensions

Length - Maximum 82.2 in 404 in 404 in 404 in 404 in 331.1 in
Width - Maximum 44.1 in 99.62 in 99.62 in 99.62 in 99.62 in 128.5 in
Height - Maximum 54.1 in 156.6 in 156.6 in 156.6 in 156.6 in 150.7 in
Dry Weight - Genset (maximum) 2490 lb 141840 lb 74970 lb 91050 lb 91050 lb 66200 lb
Length - Minimum - - - - - 262.5 in
Width - Minimum - - - - - 92 in
Height - Minimum - - - - - 99.8 in
Dry Weight - Genset (minimum) - - - - - 55100 lb
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • C280-12 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-16 Tier 4 Final Add
  • C175-16 Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Low Voltage Generator Set Add