Compare Equipment Go Back

C9.9 | DE300E0 50Hz NON CERTIFIED EMISSIONS
3616 Generator Set (Medium Speed)
3608 Generator Set (Medium Speed)
C280-12 Generator Set (Medium Speed)
C280-8 Generator Set (Medium Speed)
3608 Generator Set (Medium Speed)
3516E Generator Set

Generator Set Specifications

Maximum Rating 300 kVA 7520 kVA 4000 ekW 3575 kVA 3640 ekW (60Hz), 4850 kVA (50Hz) 2420 ekW (60Hz), 3250 kVA (50Hz) 2660 ekW 3500 kVA
Minimum Rating 275 kVA 4700 kVA 3150 ekW 2363 kVA 3300 ekW (60Hz), 4400 kVA (50Hz) 2200 ekW (60Hz), 2938 kVA (50Hz) 1830 ekW 2725 kVA
Emissions/Fuel Strategy Non-Certified Low Fuel Consumption Low Fuel, Tier 2 Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 EPA Tier 4 Final, IMO Tier 2 Low Fuel Consumption U.S. EPA Cert. Tier 2 / Low NOx
Voltage 200 to 400 Volts - 480 to 13800 Volts - - - - 380 to 11000 volts
Frequency 50 Hz 50 Hz 60 Hz 50 Hz 50 / 60 Hz 50 / 60 Hz 60 Hz 50 Hz
Speed 1500 rpm 720 & 1000 rpm 1800 rpm 750 & 1000 rpm 900 / 1000 rpm 900 / 1000 rpm 720 & 900 rpm 1500 rpm
Duty Cycle Standby, Prime Standby, Prime, Continuous Standby, Mission Critical, Prime, Continuous Standby, Prime, Continuous Prime, Continuous Prime, Continuous Standby, Prime, Continuous Standby, Mission Critical, Prime
Standby Rating - - 4000 (no fan)/3900/3620(no fan)/3500 ekW - - - - 3500/3250/3000 kVA
Prime Power Rating - - 3600 (no fan)/3500/3300 (no fan)/3180 ekW - - - - 3175/2950/2725 kVA

Engine Specifications

Engine Model C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke Water-Cooled Diesel
Bore 4.41 in 11 in 6.89 in 11 in 11 in 11 in 11 in 6.69 in
Stroke 5.87 in 11.8 in 8.66 in 11.8 in 11.8 in 11.8 in 11.8 in 8.46 in
Displacement 537.01 in³ 18032 in³ 6456.31 in³ 9064 in³ 13524 in³ 9064 in³ 9064 in³ 4765 in³
Compression Ratio 16.1:1 13:01 15.3:1 13:01 13:01 13:01 13:01 14.0:1
Aspiration Air to Air Aftercooled TA Turbo Aftercooled TA TA TA TA ATAAC
Fuel System Hydraulic electronic unit injection Direct unit injection Common Rail Direct unit injection Direct unit injection Direct unit injection Direct unit injection Electronic Unit Injection
Governor Type Adem™A4 Generator Set Monitoring System (GMS) ADEM� A4 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Adem™ A5

Generator Set Dimensions

Length - Maximum 157 in 404 in 331.1 in 404 in 404 in 404 in 404 in 318.4 in
Width - Maximum 47.5 in 99.62 in 128.5 in 99.62 in 99.62 in 99.62 in 99.62 in 104 in
Height - Maximum 73.5 in 156.6 in 150.7 in 156.6 in 156.6 in 156.6 in 156.6 in 131.6 in
Dry Weight - Genset (maximum) - 141840 lb 66200 lb 91050 lb 112690 lb 91050 lb 91050 lb 45651 lb
Length - Minimum - - 262.5 in - - - - 313.4 in
Width - Minimum - - 92 in - - - - 104 in
Height - Minimum - - 99.8 in - - - - 131.6 in
Dry Weight - Genset (minimum) - - 55100 lb - - - - 44930 lb
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C175-16 Tier 4 Final Add
  • C175-16 Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Generator Set Add