3512B Diesel Generator Set
C280-12 Generator Set (Medium Speed)
3608 Generator Set (Medium Speed)
3616 Generator Set (Medium Speed)
3516E Generator Set
3516E Low Voltage Generator Set

Generator Set Specifications

Standby Rating 1875/1750 kVA - - - 3500/3250/3000 kVA 2750 ekW 4000 (no fan)/3900/3620(no fan)/3500 ekW
Prime Power Rating 1700/1600 kVA - - - 3175/2950/2725 kVA 2500 ekW 3600 (no fan)/3500/3300 (no fan)/3180 ekW
Emissions/Fuel Strategy Low Fuel , Low Emissions EPA Tier 4 Final, IMO Tier 2 Low Fuel Consumption Low Fuel Consumption U.S. EPA Cert. Tier 2 / Low NOx Tier 2, Low NOx Low Fuel, Tier 2
Voltage 400 to 415 Volts - - - 380 to 11000 volts 416 to 13,800 Volts 480 to 13800 Volts
Frequency 50 Hz 50 / 60 Hz 60 Hz 50 Hz 50 Hz 60 Hz 60 Hz
Speed 1500 rpm 900 / 1000 rpm 720 & 900 rpm 720 & 1000 rpm 1500 rpm 1800 rpm 1800 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous Prime, Continuous Standby, Prime, Continuous Standby, Prime, Continuous Standby, Mission Critical, Prime Standby, Mission Critical, Prime Standby, Mission Critical, Prime, Continuous
Minimum Rating 1600 kVA 3300 ekW (60Hz), 4400 kVA (50Hz) 1830 ekW 4700 kVA 2725 kVA 2500 ekW 3150 ekW
Maximum Rating 1875 kVA 3640 ekW (60Hz), 4850 kVA (50Hz) 2660 ekW 7520 kVA 3500 kVA 2750 ekW 4000 ekW

Engine Specifications

Engine Model 3512B TA, V-12, 4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel 3608 I-8,4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke, Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel
Bore 6.69 in 11 in 11 in 11 in 6.69 in 6.69 in 6.89 in
Stroke 7.48 in 11.8 in 11.8 in 11.8 in 8.46 in 8.47 in 8.66 in
Stroke - HD 8.46 in - - - - - -
Displacement 3161.03 in³ 13524 in³ 9064 in³ 18032 in³ 4765 in³ 4765 in³ 6456.31 in³
Displacement - HD 3576 in³ - - - - - -
Compression Ratio 15.5:1 HD 13:01 13:01 13:01 14.0:1 14.7:1 15.3:1
Aspiration TA TA TA TA ATAAC ATAAC Turbo Aftercooled
Fuel System Electronic Unit Injection Direct unit injection Direct unit injection Direct unit injection Electronic Unit Injection EUI Common Rail
Governor Type ADEM™ A3 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) Adem™ A5 Adem™ A5 ADEM� A4

Generator Set Dimensions

Length - Minimum 212.8 in - - - 313.4 in - 262.5 in
Length - Maximum 217.1 in 404 in 404 in 404 in 318.4 in 311.9 in 331.1 in
Width - Minimum 90 in - - - 104 in - 92 in
Width - Maximum 90 in 99.62 in 99.62 in 99.62 in 104 in 104 in 128.5 in
Height - Minimum 94.9 in - - - 131.6 in - 99.8 in
Height - Maximum 94.9 in 156.6 in 156.6 in 156.6 in 131.6 in 131.6 in 150.7 in
Dry Weight - Genset (minimum) 25620 lb - - - 44930 lb - 55100 lb
Dry Weight - Genset (maximum) 26530 lb 112690 lb 91050 lb 141840 lb 45651 lb 40750 lb 66200 lb
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • C280-8 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C175-16 Generator Set Add
  • C175-16 Tier 4 Final Add
  • 3516E Low Voltage Generator Set Add