Compare Equipment Go Back

3512B Diesel Generator Set
C280-12 Generator Set (Medium Speed)
C175-16 Tier 4 Final
C280-8 Generator Set (Medium Speed)
3516E Generator Set
C175-16 Generator Set

Generator Set Specifications

Standby Rating 1875/1750 kVA - 3100(no fan)/3000 ekW - 3500/3250/3000 kVA 3365(no fan)/3250/3100(no fan)/3000 ekW
Prime Power Rating 1700/1600 kVA - 2825(no fan)/2725 ekW - 3175/2950/2725 kVA 3115(no fan)/3000/2825(no fan)/2725 ekW
Emissions/Fuel Strategy Low Fuel , Low Emissions EPA Tier 4 Final, IMO Tier 2 U.S. EPA Certified Tier 4 EPA Tier 4 Final, IMO Tier 2 U.S. EPA Cert. Tier 2 / Low NOx Low Fuel, Tier 2
Voltage 400 to 415 Volts - 480 to 13800 Volts - 380 to 11000 volts 480 to 13800 Volts
Frequency 50 Hz 50 / 60 Hz 60 Hz 50 / 60 Hz 50 Hz 60 Hz
Speed 1500 rpm 900 / 1000 rpm 1800 rpm 900 / 1000 rpm 1500 rpm 1800 RPM
Duty Cycle Standby, Mission Critical, Prime, Continuous Prime, Continuous Standby, Mission Critical, Prime, Continuous Prime, Continuous Standby, Mission Critical, Prime Standby, Mission Critical, Prime, Continuous
Minimum Rating 1600 kVA 3300 ekW (60Hz), 4400 kVA (50Hz) 2500 ekW 2200 ekW (60Hz), 2938 kVA (50Hz) 2725 kVA 2500 ekW
Maximum Rating 1875 kVA 3640 ekW (60Hz), 4850 kVA (50Hz) 3100 ekW 2420 ekW (60Hz), 3250 kVA (50Hz) 3500 kVA 3365 ekW

Engine Specifications

Engine Model 3512B TA, V-12, 4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke Water-Cooled Diesel C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Bore 6.69 in 11 in 6.89 in 11 in 6.69 in 6.89 in
Stroke 7.48 in 11.8 in 8.66 in 11.8 in 8.46 in 8.66 in
Stroke - HD 8.46 in - - - - -
Displacement 3161.03 in³ 13524 in³ 5155.88 in³ 9064 in³ 4765 in³ 6456.31 in³
Displacement - HD 3576 in³ - - - - -
Compression Ratio 15.5:1 HD 13:01 16.7:1 13:01 14.0:1 16.7:1
Aspiration TA TA Turbo Aftercooled TA ATAAC Turbo Aftercooled
Fuel System Electronic Unit Injection Direct unit injection EUI Direct unit injection Electronic Unit Injection Common Rail
Governor Type ADEM™ A3 Generator Set Monitoring System (GMS) ADEM� A4 Generator Set Monitoring System (GMS) Adem™ A5 ADEM� A4

Generator Set Dimensions

Length - Minimum 212.8 in - 242.77 in - 313.4 in 250.9 in
Length - Maximum 217.1 in 404 in 320 in 404 in 318.4 in 330.6 in
Width - Minimum 90 in - 82.7 in - 104 in 82.7 in
Width - Maximum 90 in 99.62 in 122.8 in 99.62 in 104 in 124.3 in
Height - Minimum 94.9 in - 127.2 in - 131.6 in 86.9 in
Height - Maximum 94.9 in 156.6 in 142.3 in 156.6 in 131.6 in 134.2 in
Dry Weight - Genset (minimum) 25620 lb - 42750 lb - 44930 lb 42750 lb
Dry Weight - Genset (maximum) 26530 lb 112690 lb 45114 lb 91050 lb 45651 lb 57774 lb
Add a Similar Product:
  • 3616 Generator Set (Medium Speed) Add
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-20 Add
  • 3606 Generator Set (Medium Speed) Add
  • 3516E Low Voltage Generator Set Add