Compare Equipment Go Back

3512B Diesel Generator Set
3606 Generator Set (Medium Speed)
C280-12 Generator Set (Medium Speed)
C175-16 Generator Set
3516E Low Voltage Generator Set
C280-8 Generator Set (Medium Speed)
3516E Generator Set
3516E Low Voltage Generator Set

Generator Set Specifications

Standby Rating 1875/1750 kVA - - 3365(no fan)/3250/3100(no fan)/3000 ekW 3000 ekW - 3500/3250/3000 kVA 2750 ekW
Prime Power Rating 1700/1600 kVA - - 3115(no fan)/3000/2825(no fan)/2725 ekW 2725 ekW - 3175/2950/2725 kVA 2500 ekW
Emissions/Fuel Strategy Low Fuel , Low Emissions Low Fuel Consumption EPA Tier 4 Final, IMO Tier 2 Low Fuel, Tier 2 Tier 2 EPA Tier 4 Final, IMO Tier 2 U.S. EPA Cert. Tier 2 / Low NOx Tier 2, Low NOx
Voltage 400 to 415 Volts - - 480 to 13800 Volts 416 to 13,800 Volts - 380 to 11000 volts 416 to 13,800 Volts
Frequency 50 Hz 50 Hz 50 / 60 Hz 60 Hz 60 Hz 50 / 60 Hz 50 Hz 60 Hz
Speed 1500 rpm 750 & 1000 rpm 900 / 1000 rpm 1800 RPM 1800 rpm 900 / 1000 rpm 1500 rpm 1800 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous Continuous Prime, Continuous Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime Prime, Continuous Standby, Mission Critical, Prime Standby, Mission Critical, Prime
Minimum Rating 1600 kVA 1775 kVA 3300 ekW (60Hz), 4400 kVA (50Hz) 2500 ekW 2725 ekW 2200 ekW (60Hz), 2938 kVA (50Hz) 2725 kVA 2500 ekW
Maximum Rating 1875 kVA 2688 kVA 3640 ekW (60Hz), 4850 kVA (50Hz) 3365 ekW 3000 ekW 2420 ekW (60Hz), 3250 kVA (50Hz) 3500 kVA 2750 ekW

Engine Specifications

Engine Model 3512B TA, V-12, 4-Stroke Water-Cooled Diesel 3606 I-6, 4-Stroke Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke, Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke, Water-Cooled Diesel
Bore 6.69 in 11 in 11 in 6.89 in 6.69 in 11 in 6.69 in 6.69 in
Stroke 7.48 in 11.8 in 11.8 in 8.66 in 8.47 in 11.8 in 8.46 in 8.47 in
Stroke - HD 8.46 in - - - - - - -
Displacement 3161.03 in³ 6762 in³ 13524 in³ 6456.31 in³ 4765 in³ 9064 in³ 4765 in³ 4765 in³
Displacement - HD 3576 in³ - - - - - - -
Compression Ratio 15.5:1 HD 13:01 13:01 16.7:1 13.9:1 / 14.3:1 13:01 14.0:1 14.7:1
Aspiration TA TA TA Turbo Aftercooled ATAAC TA ATAAC ATAAC
Fuel System Electronic Unit Injection Direct unit injection Direct unit injection Common Rail MEUI Direct unit injection Electronic Unit Injection EUI
Governor Type ADEM™ A3 Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) ADEM� A4 Adem™ A5 Generator Set Monitoring System (GMS) Adem™ A5 Adem™ A5

Generator Set Dimensions

Length - Minimum 212.8 in - - 250.9 in - - 313.4 in -
Length - Maximum 217.1 in 404 in 404 in 330.6 in 302.4 in 404 in 318.4 in 311.9 in
Width - Minimum 90 in - - 82.7 in - - 104 in -
Width - Maximum 90 in 99.62 in 99.62 in 124.3 in 113.2 in 99.62 in 104 in 104 in
Height - Minimum 94.9 in - - 86.9 in - - 131.6 in -
Height - Maximum 94.9 in 156.6 in 156.6 in 134.2 in 143.3 in 156.6 in 131.6 in 131.6 in
Dry Weight - Genset (minimum) 25620 lb - - 42750 lb - - 44930 lb -
Dry Weight - Genset (maximum) 26530 lb 74970 lb 112690 lb 57774 lb 44930 lb 91050 lb 45651 lb 40750 lb
Add a Similar Product:
  • 3616 Generator Set (Medium Speed) Add
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • C175-20 Add
  • C175-16 Tier 4 Final Add
  • 3516E Generator Set Add