Compare Equipment Go Back

3512B Diesel Generator Set
3516E Low Voltage Generator Set
C280-12 Generator Set (Medium Speed)
3516E Generator Set
3616 Generator Set (Medium Speed)
C175-16 Tier 4 Final
C280-8 Generator Set (Medium Speed)

Generator Set Specifications

Standby Rating 1875/1750 kVA 3000 ekW - 3500/3250/3000 kVA - 4000 (no fan)/3900/3620(no fan)/3500 ekW 3100(no fan)/3000 ekW -
Prime Power Rating 1700/1600 kVA 2725 ekW - 3175/2950/2725 kVA - 3600 (no fan)/3500/3300 (no fan)/3180 ekW 2825(no fan)/2725 ekW -
Emissions/Fuel Strategy Low Fuel , Low Emissions Tier 2 EPA Tier 4 Final, IMO Tier 2 U.S. EPA Cert. Tier 2 / Low NOx Low Fuel Consumption Low Fuel, Tier 2 U.S. EPA Certified Tier 4 EPA Tier 4 Final, IMO Tier 2
Voltage 400 to 415 Volts 416 to 13,800 Volts - 380 to 11000 volts - 480 to 13800 Volts 480 to 13800 Volts -
Frequency 50 Hz 60 Hz 50 / 60 Hz 50 Hz 50 Hz 60 Hz 60 Hz 50 / 60 Hz
Speed 1500 rpm 1800 rpm 900 / 1000 rpm 1500 rpm 720 & 1000 rpm 1800 rpm 1800 rpm 900 / 1000 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime Prime, Continuous Standby, Mission Critical, Prime Standby, Prime, Continuous Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime, Continuous Prime, Continuous
Minimum Rating 1600 kVA 2725 ekW 3300 ekW (60Hz), 4400 kVA (50Hz) 2725 kVA 4700 kVA 3150 ekW 2500 ekW 2200 ekW (60Hz), 2938 kVA (50Hz)
Maximum Rating 1875 kVA 3000 ekW 3640 ekW (60Hz), 4850 kVA (50Hz) 3500 kVA 7520 kVA 4000 ekW 3100 ekW 2420 ekW (60Hz), 3250 kVA (50Hz)

Engine Specifications

Engine Model 3512B TA, V-12, 4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke, Water-Cooled Diesel C280-12, V-12,4-Stroke Water-Cooled Diesel 3516E, V-16, 4-Stroke Water-Cooled Diesel 3616 V-16, 4-Stroke Water-Cooled Diesel C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel C280-8, I-8,4-Stroke Water-Cooled Diesel
Bore 6.69 in 6.69 in 11 in 6.69 in 11 in 6.89 in 6.89 in 11 in
Stroke 7.48 in 8.47 in 11.8 in 8.46 in 11.8 in 8.66 in 8.66 in 11.8 in
Stroke - HD 8.46 in - - - - - - -
Displacement 3161.03 in³ 4765 in³ 13524 in³ 4765 in³ 18032 in³ 6456.31 in³ 5155.88 in³ 9064 in³
Displacement - HD 3576 in³ - - - - - - -
Compression Ratio 15.5:1 HD 13.9:1 / 14.3:1 13:01 14.0:1 13:01 15.3:1 16.7:1 13:01
Aspiration TA ATAAC TA ATAAC TA Turbo Aftercooled Turbo Aftercooled TA
Fuel System Electronic Unit Injection MEUI Direct unit injection Electronic Unit Injection Direct unit injection Common Rail EUI Direct unit injection
Governor Type ADEM™ A3 Adem™ A5 Generator Set Monitoring System (GMS) Adem™ A5 Generator Set Monitoring System (GMS) ADEM� A4 ADEM� A4 Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Minimum 212.8 in - - 313.4 in - 262.5 in 242.77 in -
Length - Maximum 217.1 in 302.4 in 404 in 318.4 in 404 in 331.1 in 320 in 404 in
Width - Minimum 90 in - - 104 in - 92 in 82.7 in -
Width - Maximum 90 in 113.2 in 99.62 in 104 in 99.62 in 128.5 in 122.8 in 99.62 in
Height - Minimum 94.9 in - - 131.6 in - 99.8 in 127.2 in -
Height - Maximum 94.9 in 143.3 in 156.6 in 131.6 in 156.6 in 150.7 in 142.3 in 156.6 in
Dry Weight - Genset (minimum) 25620 lb - - 44930 lb - 55100 lb 42750 lb -
Dry Weight - Genset (maximum) 26530 lb 44930 lb 112690 lb 45651 lb 141840 lb 66200 lb 45114 lb 91050 lb
Add a Similar Product:
  • C280-16 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3612 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • 3608 Generator Set (Medium Speed) Add
  • C280-6 Generator Set (Medium Speed) Add
  • 3606 Generator Set (Medium Speed) Add
  • C175-16 Generator Set Add
  • 3516E Low Voltage Generator Set Add
  • 3516E Generator Set Add