Three engine emission options are available: 1. Meets U.S. EPA Tier 4 Final, EU Stage V, and Japan 2014 emission standards. 2. Meets Brazil MAR-1 emission standards, equivalent to U.S. EPA Tier 3 and EU Stage IIIA. 3. Meets China Nonroad Stage IV emissio
-
-
Note (2)
Net power advertised is the power available at the flywheel when the engine is equipped with fan at minimum speed, air intake system, exhaust system, and alternator.
-
-
Operating Specifications
Operating Weight
112574 lb
-
-
Bucket Capacity Range
4.7-13 m3 (6.2-17 yd3)
-
-
Rated Payload - Quarry Face
12.5 t
-
-
Rated Payload - Loose Material
16 t
-
-
Cat Truck Match - Standard
770 - 772
-
-
Cat Truck Match - High Lift
773 - 775
-
-
Transmission
Transmission Type
Cat planetary powershift
-
-
Forward - 1
4 mile/h
-
-
Forward - 2
7.2 mile/h
-
-
Forward - 3
12.7 mile/h
-
-
Forward - 4
21.6 mile/h
-
-
Reverse - 1
4.7 mile/h
-
-
Reverse - 2
8.3 mile/h
-
-
Reverse - 3
14.4 mile/h
-
-
Direct Drive - Forward 1
Lock-up disabled
-
-
Direct Drive - Forward 2
7.8 mile/h
-
-
Direct Drive - Forward 3
13.9 mile/h
-
-
Direct Drive - Forward 4
24.4 mile/h
-
-
Direct Drive - Reverse 1
5 mile/h
-
-
Direct Drive - Reverse 2
8.9 mile/h
-
-
Direct Drive - Reverse 3
15.8 mile/h
-
-
Hydraulic System - Lift/Tilt
Lift/Tilt System - Circuit
EH- Positive Flow Control, Flow Sharing
-
-
Lift/Tilt System - Pump
Variable displacement piston
-
-
Maximum Flow at 1,400-1,860 rpm
153 gal/min
-
-
Relief Valve Setting - Lift/Tilt
4757 psi
-
-
Cylinders, Double Acting - Lift, Bore and Stroke
210 mm × 1050 mm (8.7 in × 41.3 in)
-
-
Cylinders, Double Acting - Tilt, Bore and Stroke
266 mm × 685 mm (8.7 in × 27 in)
-
-
Pilot System
Variable displacement piston
-
-
Relief Valve Setting - Main
551 psi
-
-
Hydraulic Cycle Time (1,400-1,860 rpm)
Rack Back
4.5 s
-
-
Raise
8 s
-
-
Dump
2.2 s
-
-
Lower Float Down
3.5 s
-
-
Total Hydraulic Cycle Time - Empty Bucket
18.2 s
-
-
Hydraulic System - Steering
Steering System - Circuit
Pilot, load sensing
-
-
Steering System - Pump
Piston, variable displacement
-
-
Maximum Flow at 1,400-1,600 rpm
71.3 gal/min
-
-
Relief Valve Setting - Steering
4351 psi
-
-
Total Steering Angle
86 °
-
-
Steering Cycle Times - High Idle
3.4 s
-
-
Steering Cycle Times - Low Idle
5.6 s
-
-
Air Conditioning System
Air Conditioning
• The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. • If equipped with R134a (Global Warming Potential = 1430), the system
-
-
Axles
Front
Fixed
-
-
Rear
Trunnion
-
-
Oscillation Angle
13 °
-
-
Brakes
Brakes
ISO 3450:2011
-
-
Operator's Cab
ROPS/FOPS
ROPS/FOPS meet ISO 3471:2008 and ISO 3449:2005 Level II standards
-
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
73 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
111 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)**
109 dB(A)
-
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives.”
-
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701.
-
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Sound Performance - Tier 3 / Stage IIIA
Operator Sound Pressure Level (ISO 6396:2008)
73 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
112 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)**
110 dB(A)
-
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives.”
-
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701.
-
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Service Refill Capacities
Fuel Tank
188 gal (US)
-
-
Cooling System
31.7 gal (US)
-
-
Coolant (Validated by Test Cell Fill Quantities)
33 gal (US)
-
-
Crankcase
15.9 gal (US)
-
-
Diesel Exhaust Fluid Tank (For Tier 4 Final/Stage V Only)
8.7 gal (US)
-
-
Transmission
24.3 gal (US)
-
-
Transmission - Validated by Test Cell Fill Quantities
29 gal (US)
-
-
Differential - Final Drives - Front
49.1 gal (US)
-
-
Differential - Final Drives - Rear
49.1 gal (US)
-
-
Hydraulic System Factory Fill
125.5 gal (US)
-
-
Hydraulic System - Tank Only
63.4 gal (US)
-
-
Note