Cylinders, Double Acting - Left and Right Tilt, Bore and Stroke
-
101.6 mm × 234 mm (4.0 in × 9.2 in)
-
Pilot System
-
Open center, fixed displacement gear
-
Pilot Relief Valve Setting
-
3046 psi
-
Hydraulic System - Steering
Steering System - Circuit
Pilot, load sensing
Pilot, load sensing
-
Steering System - Pump
Piston, variable displacement
Variable displacement piston
-
Minimum Turning Radius - Over Blade
34 ft
-
-
Total Steering Angle
35 °
72°
-
Maximum Flow
94.3 gal/min
-
-
Relief Valve Setting
4500 psi
-
-
Maximum Flow at 2,200 rpm
-
38.8 gal/min
-
Relief Valve Setting - Steering
-
4003 psi
-
Steering Cycle Times - High Idle
-
3 s
-
Steering Cycle Times - Low Idle
-
8.2 s
-
Service Refill Capacities
Fuel Tank - Standard
286.6 gal (US)
-
-
Cooling System
54.9 gal (US)
-
-
Crankcase
20 gal (US)
-
-
Transmission
29.1 gal (US)
13.2 gal (US)
-
Differential - Final Drives - Front
71.6 gal (US)
17.2 gal (US)
-
Differential - Final Drives - Rear
68.9 gal (US)
17.2 gal (US)
-
Hydraulic System - Implement and Hydraulic Fan
68.9 gal (US)
-
-
Hydraulic System - Steering and Braking
34.9 gal (US)
-
-
Fuel Tank
-
132.1 gal (US)
-
Diesel Exhaust Fluid Tank
-
4.2 gal (US)
-
Cooling Systems - Tier 4 Final/EU Stage V
-
21.4 gal (US)
-
Cooling Systems - Brazil MAR-1 and China NonroadStage III, equivalent to Tier 3/EU Stage IIIA
-
19.3 gal (US)
-
Engine Crankcase
-
5.3 gal (US)
-
Hydraulic System - Implement/Steering
-
34.1 gal (US)
-
Hydraulic Tank Only
-
19.8 gal (US)
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a (Global Warming Potential = 1430). The system contains 1.8 kg of refrigerant which has a CO2 equivalent of 2.574 metric tonnes.
-
-
Axles
Front
Fixed
Planetary – Fixed
-
Rear
Trunnion
Planetary – Oscillating
-
Oscillation Angle
8.5 °
±10°
-
Brakes
Brakes
Meets ISO 3540:2011
-
-
Sound Performance - Standard
Operator Sound Level (ISO 6396:2008)
69 dB(A)
-
-
Machine Sound Level (ISO 6395:2008)
115 dB(A)
-
-
Sound Performance - Suppression
Operator Sound Level (ISO 6396:2008)
69 dB(A)
-
-
Machine Sound Level (ISO 6395:2008)
113 dB(A)
-
-
Cab
ROPS/FOPS
ISO 3471:2008 and ISO 3449:2005 Level II Standards
-
-
Dimensions (Approximate)
Height - Top of ROPS
17.2 ft
-
-
Height - Top of Exhaust Pipe
16.6 ft
11.3 ft
-
Height - Top of Hood
12.7 ft
8.7 ft
-
Ground Clearance
2 ft
-
-
Centerline of Front Axle to Hitch
7.5 ft
5.5 ft
-
Centerline of Rear Axle to Edge of Bumper
12.5 ft
-
-
Wheel Base
15.1 ft
11 ft
-
Length - With Blade on Ground
36.5 ft
-
-
Height to Top of Beacon
-
13.1 ft
-
Height - Top of Cab
-
12.1 ft
-
Height to Top of Radiator Guard
-
8 ft
-
Ground Clearance to Hitch
-
1.4 ft
-
Ground Clearance to Transmission Guard
-
1.4 ft
-
Ground Clearance to Bottom of Bumper
-
2.3 ft
-
Centerline of Rear Axle to Bumper
-
6.5 ft
-
Width over Platform
-
10.3 ft
-
Overall Length to Front Tire
-
21 ft
-
Overall Machine Length with Straight Blade
-
23.6 ft
-
Overall Machine Length with Coal Blade
-
25.5 ft
-
Engine - Tier 4 Final/EU Stage V
Engine Model
-
Cat C7.1
-
Net Power (SAE J1349:2011)
-
249 HP
-
Net Power (ISO 9249:2007)
-
249 HP
-
Emissions
-
U.S. EPA Tier 4 Final/EU Stage V
-
Rated Speed
-
2200 r/min
-
Gross Power (SAE J1995:2014)
-
284 HP
-
Engine Power (ISO 14396:2002)
-
275 HP
-
Peak Torque - 1,400 rpm
-
902 lb/ft
-
Torque Rise
-
52%
-
Bore
-
4.1 in
-
Stroke
-
5.3 in
-
Displacement
-
427.8 in³
-
High Idle Speed
-
2270 r/min
-
Low Idle Speed
-
800 r/min
-
Maximum Altitude without Derating
-
9842.5 ft
-
Note
-
Net power advertised is the power available at the engine flywheel when the engine is equipped with a fan, air cleaner, clean emissions module and alternator.
-
Operating Specifications - Tier 4 Final/EU Stage V
Operating Weight
-
48526 lb
-
Scoops
Chip Scoop Doze Capacity
-
37.9 yd³
-
Chip Scoop Carry Capacity
-
19 yd³
-
Engine - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA
Engine Model
-
Cat C7.1
-
Emissions
-
Brazil MAR-1 and China Nonroad Stage III, equivalent to Tier 3/EU Stage IIIA
-
Rated Speed
-
2200 r/min
-
Net Power (SAE J1349:2011)
-
249 HP
-
Gross Power (SAE J1995:2014)
-
286 HP
-
Engine Power (ISO 14396:2002)
-
275 HP
-
Peak Torque - 1,400 rpm
-
749 lb/ft
-
Torque Rise
-
26%
-
Bore
-
4.1 in
-
Stroke
-
5.3 in
-
Displacement
-
427.8 in³
-
High Idle Speed
-
2270 r/min
-
Operating Specifications - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA
Operating Weight
-
47887 lb
-
Operating Specifications - Tier 4 Final/EU Stage V - Scoop
Operating Weight
-
52280 lb
-
Operating Specifications - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA - Scoop
Operating Weight
-
51639 lb
-
Braking System
Service Brakes
-
Single Disc Wet (enclosed) 4 WHL
-
Parking Brake
-
Drum and Shoe, Spring Applied, Hydraulic Released
-
Sound Performance - Tier 4 Final/EU Stage V - Standard
Operator Sound Level (ISO 6396)
-
70 dB(A)
-
Machine Sound Level (ISO 6395)
-
111 dB(A)
-
Note (1)
-
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
Note (2)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Note (3)
-
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
Note (4)
-
The operator sound pressure level uncertainty is ± 2 dB(A)
-
Sound Performance - Tier 4 Final/EU Stage V - Suppression
Operator Sound Level (ISO 6396)
-
70 dB(A)
-
Machine Sound Level (ISO 6395)
-
109 dB(A)
-
Note (1)
-
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
Note (2)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Note (3)
-
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
Note (4)
-
The operator sound pressure level uncertainty is ± 2 dB(A).
-
Sound Performance - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA - Standard
Operator Sound Level (ISO 6396)
-
70 dB(A)
-
Machine Sound Level (ISO 6395)
-
112 dB(A)
-
Note (1)
-
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
Note (2)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Note (3)
-
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
Note (4)
-
The operator sound pressure level uncertainty is ± 2 dB(A).
-
Sound Performance - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA - Suppression
Operator Sound Level (ISO 6396)
-
70 dB(A)
-
Machine Sound Level (ISO 6395)
-
110 dB(A)
-
Note (1)
-
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
Note (2)
-
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Note (3)
-
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
Note (4)
-
The operator sound pressure level uncertainty is ± 2 dB(A).