The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a (Global Warming Potential = 1430). The system contains 1.8 kg of refrigerant which has a CO2 equivalent of 2.574 metric tonnes.
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a (Global Warming Potential = 1430). The system contains 1.8 kg of refrigerant which has a CO2 equivalent of 2.574 metric tonnes.
-
Axles
Front
Fixed
Fixed
-
Rear
Trunnion
Trunnion
-
Oscillation Angle
±13°
8.5 °
-
Brakes
Brakes
ISO 3450: 2011
Meets ISO 3540:2011
-
Sound Performance - Tier 4 Final/EU Stage V - Standard
Operator Sound Level (ISO 6396)
72 dB(A)
-
-
Machine Sound Level (ISO 6395)
113 dB(A)
-
-
Sound Performance - Tier 4 Final/EU Stage V - Suppression
Operator Sound Level (ISO 6396)
72 dB(A)
-
-
Machine Sound Level (ISO 6395)
109 dB(A)
-
-
Dimensions
Height - Top of Exhaust Stack
15.9 ft
-
-
Height - Top of Air Cleaner
12.8 ft
-
-
Height - Top of Hood
10.9 ft
-
-
Ground Clearance - Bumper
3.1 ft
-
-
Centerline of Rear Axle to Edge of Bumper
10.5 ft
-
-
Wheel Base
14.9 ft
-
-
Length - Front of Tire
28.4 ft
-
-
Length - Straight Blade on Ground
32.6 ft
-
-
Centerline of Front Axle to Hitch
7.5 ft
-
-
Length - Universal Blade on Ground
34.4 ft
-
-
Ground Clearance
1.7 ft
-
-
Height - Top of Cab
13.7 ft
-
-
Scoops
Chip Scoop Carry Capacity
35 yd³
-
-
Chip Scoop Doze Capacity
70 yd³
-
-
Coal Scoop Carry Capacity
30 yd³
-
-
Coal Scoop Doze Capacity
60 yd³
-
-
Sound Performance - Standard
Operator Sound Level (ISO 6396:2008)
-
69 dB(A)
-
Machine Sound Level (ISO 6395:2008)
-
115 dB(A)
-
Sound Performance - Suppression
Operator Sound Level (ISO 6396:2008)
-
69 dB(A)
-
Machine Sound Level (ISO 6395:2008)
-
113 dB(A)
-
Cab
ROPS/FOPS
-
ISO 3471:2008 and ISO 3449:2005 Level II Standards