Cat® BDP1000 Bi-Directional Power Inverter
|
|
EMCP 4.4 Master Control Panel
|
|
Temporary Connection Boxes
|
Generator Set Specifications |
Frequency |
60 Hz |
- |
- |
- |
- |
- |
Natural Gas Rating |
350 ekW |
- |
- |
- |
- |
- |
Emissions/Fuel Strategy |
U.S. EPA Certified for Stationary Emergency Application and Non-Emergency Applications |
- |
- |
- |
- |
- |
Fuel Type |
Natural Gas |
- |
- |
- |
- |
- |
RPM |
1800 |
- |
- |
- |
- |
- |
Voltage |
208 - 600 VAC |
- |
- |
- |
- |
- |
Engine Specifications |
Engine Model |
Cat® CG18 In-line 6, 4-cycle Natural
Gas |
- |
- |
- |
- |
- |
Fuel System |
Gas mixer, Venturi |
- |
- |
- |
- |
- |
Aspiration |
Turbocharged - Air-to-Air Aftercooled |
- |
- |
- |
- |
- |
Governor Type |
Electronic |
- |
- |
- |
- |
- |
Displacement |
1106.3 in³ |
- |
- |
- |
- |
- |
Compression Ratio |
10.5:1 |
- |
- |
- |
- |
- |
Bore |
5.7 in |
- |
- |
- |
- |
- |
Stroke |
7.2 in |
- |
- |
- |
- |
- |
Generator Set Dimensions |
Length |
154 in |
- |
- |
- |
- |
- |
Width |
73 in |
- |
- |
- |
- |
- |
Height |
82 in |
- |
- |
- |
- |
- |
Weight |
10721 lb |
- |
- |
- |
- |
- |
Technical Summary |
Application |
- |
Energy Storage System |
LV and MV ( 208V - 38 kV |
LV and MV (208V - 38 kV) |
- |
EMERGENCY, LEGALLY REQUIRED EMERGENCY AND STANDBY |
Module Type |
- |
Integral part of Power Grid Stabilization and Energy Time Shift modules |
- |
- |
- |
LUG-TO-LUG, CAMLOCK AND ENCLOSED CIRCUIT BREAKER |
Rated Power |
- |
1000 kVA (1000kW 1PF) |
- |
- |
- |
200 - 4000 AMPS |
Configuration |
- |
- |
Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications |
Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source. |
- |
- |
Modes of Operation |
- |
- |
Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power |
Emergency standby, island, utility paralleling |
- |
- |
Generator Protective Devices |
ANSI Protective Devices |
- |
- |
15/25, 27/59, 81 O/U, 32, 40, 50, 51 |
15/25, 27/59, 81 O/U, 32, 40, 50, 51 |
- |
- |
Utility Protective Devices |
ANSI Protective Devices |
- |
- |
15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86 |
15/25. 27/59, 81 O/U, 32,47 (Industrial Grade) |
- |
- |
Environmental Parameters |
Certifications |
- |
- |
IBS, CBC, UBC & OSHPD Certified |
IBC, CBC, UBC & OSHPD Certified |
- |
- |
Control Panel Enclosure |
- |
- |
NEMA 1 or NEMA 3R, Freestanding Construction |
NEMA 1 wall-mounted construction |
- |
- |
Operating Temperature |
- |
- |
0 degrees to 50 degrees C |
0°C to 50°C |
- |
- |
Storage Temperature |
- |
- |
-20 degrees C to +60 degrees C |
-20°C to +60°C |
- |
- |
Low Voltage Standards |
- |
- |
NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 |
NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 |
- |
- |
Medium Voltage Standards |
- |
- |
NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 |
NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 |
- |
- |
Generator Set |
Rating Prime |
- |
- |
- |
- |
550 kVA |
- |
Frequency |
- |
- |
- |
- |
50/60 Hz |
- |
Voltage |
- |
- |
- |
- |
220 - 480 V |
- |
Fuel/Emissions Strategy |
- |
- |
- |
- |
EU Stage V |
- |
Engine |
Engine |
- |
- |
- |
- |
Cat® C18 |
- |
Fuel |
- |
- |
- |
- |
Diesel |
- |
Dimensions |
Width |
- |
- |
- |
- |
80.3 in |
- |
Height |
- |
- |
- |
- |
90.5 in |
- |
Length |
- |
- |
- |
- |
213.3 in |
- |
Weight - With Lube Oil and Coolant |
- |
- |
- |
- |
14860 lb |
- |
Fuel Consumption |
100% Load 60 Hz |
- |
- |
- |
- |
34.3 gal/hr |
- |
100% Load 50 Hz |
- |
- |
- |
- |
33.4 gal/hr |
- |
75% Load 60 Hz |
- |
- |
- |
- |
26.13 gal/hr |
- |
75% Load 50 Hz |
- |
- |
- |
- |
24.9 gal/hr |
- |
Noise rating (with enclosure) |
Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) |
- |
- |
- |
- |
79.19 |
- |