Cat® BDP1000 Bi-Directional Power Inverter
|
Engine Paralleling and Integration Control (EPIC)
|
Cat Customizable Switchgear and Controls
|
Generator Set Specifications |
Frequency |
60 Hz |
- |
- |
- |
Natural Gas Rating |
350 ekW |
- |
- |
- |
Emissions/Fuel Strategy |
U.S. EPA Certified for Stationary Emergency Application and Non-Emergency Applications |
- |
- |
- |
Fuel Type |
Natural Gas |
- |
- |
- |
RPM |
1800 |
- |
- |
- |
Voltage |
208 - 600 VAC |
- |
- |
- |
Engine Specifications |
Engine Model |
Cat® CG18 In-line 6, 4-cycle Natural
Gas |
- |
- |
- |
Fuel System |
Gas mixer, Venturi |
- |
- |
- |
Aspiration |
Turbocharged - Air-to-Air Aftercooled |
- |
- |
- |
Governor Type |
Electronic |
- |
- |
- |
Displacement |
1106.3 in³ |
- |
- |
- |
Compression Ratio |
10.5:1 |
- |
- |
- |
Bore |
5.7 in |
- |
- |
- |
Stroke |
7.2 in |
- |
- |
- |
Generator Set Dimensions |
Length |
154 in |
- |
- |
- |
Width |
73 in |
- |
- |
- |
Height |
82 in |
- |
- |
- |
Weight |
10721 lb |
- |
- |
- |
Technical Summary |
Application |
- |
Energy Storage System |
LV and MV (208V-27kV) |
LV and MV ( 208V - 38 kV) 50 / 60 Hz |
Module Type |
- |
Integral part of Power Grid Stabilization and Energy Time Shift modules |
- |
- |
Rated Power |
- |
1000 kVA (1000kW 1PF) |
- |
- |
Configuration |
- |
- |
Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control) |
Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc |
Modes of Operation |
- |
- |
Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel) |
All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow |
Generator Protective Devices |
ANSI Protective Devices |
- |
- |
15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade) |
Per customer specification |
Utility Protective Devices |
ANSI Protective Devices |
- |
- |
15/25. 27/59, 81 O/U, 32,47 (Industrial Grade) |
Per customer specification |
Environmental Parameters |
Certifications |
- |
- |
UL / cUL 508A |
Per customer specification |
Control Panel Enclosure |
- |
- |
NEMA 12 |
Per customer specification |
Operating Temperature |
- |
- |
0°C to 55°C |
Per customer specification |
Storage Temperature |
- |
- |
-20°C to 60°C |
Per customer specification |
Low Voltage Standards |
- |
- |
- |
Per customer specification |
Medium Voltage Standards |
- |
- |
- |
Per customer specification |