Two engine emission options are available: 1. Meets U.S. EPA Tier 4 Final, EU Stage V, and Japan emission standards. 2. Meets Brazil MAR-1 emission standards, equivalent to U.S. EPA Tier 3 and EU Stage IIIA.
Three engine emission options are available: 1. Meets U.S. EPA Tier 4 Final, EU Stage V, and Japan 2014 emission standards. 2. Meets Brazil MAR-1 emission standards, equivalent to U.S. EPA Tier 3 and EU Stage IIIA. 3. Meets China Nonroad Stage IV emissio
-
Note (2)
Net power advertised is the power available at the flywheel when the engine is equipped with fan at minimum speed, air intake system, exhaust system, and alternator.
Net power advertised is the power available at the flywheel when the engine is equipped with fan at minimum speed, air intake system, exhaust system, and alternator.
-
Note (3)
Net power at the flywheel when the fan is at maximum speed is 304 kW / 408 hp per SAE reference conditions.
-
-
Engine Power - ISO 14396:2002
-
580 hp
-
Peak Torque - 1,200 rpm
-
2104 lbf·ft
-
Transmission
Transmission Type
Cat planetary power shift
Cat planetary powershift
-
Forward - 1
5 mile/h
4 mile/h
-
Forward - 2
8 mile/h
7.2 mile/h
-
Reverse - 1
5 mile/h
4.7 mile/h
-
Reverse - 2
8 mile/h
8.3 mile/h
-
Direct Drive - Forward 1
Lock-up disabled
Lock-up disabled
-
Direct Drive - Forward 2
8 mile/h
7.8 mile/h
-
Direct Drive - Forward 3
14 mile/h
13.9 mile/h
-
Direct Drive - Forward 4
24 mile/h
24.4 mile/h
-
Direct Drive - Reverse 1
Lock-up disabled
5 mile/h
-
Direct Drive - Reverse 2
9 mile/h
8.9 mile/h
-
Direct Drive - Reverse 3
16 mile/h
15.8 mile/h
-
Direct Drive - Reverse 4
25.4 mile/h
-
-
Note
Travel speeds based on 35/65-R33 tires.
-
-
Forward - 3
-
12.7 mile/h
-
Forward - 4
-
21.6 mile/h
-
Reverse - 3
-
14.4 mile/h
-
Hydraulic System - Lift/Tilt
Lift/Tilt System - Circuit
EH - Load Sense
EH- Positive Flow Control, Flow Sharing
-
Lift/Tilt System - Pump
Variable displacement piston
Variable displacement piston
-
Maximum Flow at 2,165 rpm
159 gal/min
-
-
Relief Valve Setting - Lift/Tilt
4598 psi
4757 psi
-
Cylinders, Double Acting - Lift, Bore and Stroke
190 mm x 1216 mm (7.5 in x 48 in)
210 mm × 1050 mm (8.7 in × 41.3 in)
-
Cylinders, Double Acting - Tilt, Bore and Stroke
170 mm x 722 mm (6.7 in x 28.4 in)
266 mm × 685 mm (8.7 in × 27 in)
-
Pilot System
Variable displacement piston
Variable displacement piston
-
Relief Valve Setting
500 psi
-
-
Maximum Flow at 1,400-1,860 rpm
-
153 gal/min
-
Relief Valve Setting - Main
-
551 psi
-
Hydraulic Cycle Times
Rack Back
3.8 s
-
-
Raise
7.5 s
-
-
Dump
3 s
-
-
Lower Float Down
4.6 s
-
-
Total Hydraulic Cycle Time - Empty Bucket
18.9 s
-
-
Hydraulic System - Steering
Steering System - Circuit
Pilot, load sensing
Pilot, load sensing
-
Steering System - Pump
Piston, variable displacement
Piston, variable displacement
-
Maximum Flow at 2,165 rpm
52 gal/min
-
-
Relief Valve Setting - Steering
4000 psi
4351 psi
-
Total Steering Angle
70°
86 °
-
Steering Cycle Times - High Idle
3 s
3.4 s
-
Steering Cycle Times - Low Idle
5.2 s
5.6 s
-
Maximum Flow at 1,400-1,600 rpm
-
71.3 gal/min
-
Air Conditioning System
Air Conditioning
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
• The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. • If equipped with R134a (Global Warming Potential = 1430), the system
-
Axles
Front
Fixed
Fixed
-
Rear
Trunnion
Trunnion
-
Oscillation Angle
+/-12.5°
13 °
-
Brakes
Brakes
ISO 3450:2011
ISO 3450:2011
-
Operator's Cab
ROPS/FOPS
Rollover Protective Structure/Falling Objects Protective Structure (ROPS/FOPS) meet ISO 3471:2008 and ISO 3449:2005 Level II standards
ROPS/FOPS meet ISO 3471:2008 and ISO 3449:2005 Level II standards
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
73 dB(A)
73 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
113 dB(A)
111 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)**
110 dB(A)
109 dB(A)
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives.”
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives.”
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701.
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701.
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Sound Performance - Tier 3 / Stage IIIA
Operator Sound Pressure Level (ISO 6396:2008)
74 dB(A)
73 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)
113 dB(A)
112 dB(A)
-
Operator Sound Pressure Level (ISO 6396:2008)*
73 dB(A)
72 dB(A)
-
Machine Sound Power Level (ISO 6395:2008)**
110 dB(A)
110 dB(A)
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives.”
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives.”
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701.
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701.
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
Service Refill Capacities
Fuel Tank
141 gal (US)
188 gal (US)
-
Cooling System
27 gal (US)
31.7 gal (US)
-
Engine Crankcase
9 gal (US)
-
-
Diesel Exhaust Fluid Tank
5.5 gal (US)
-
-
Transmission
20 gal (US)
24.3 gal (US)
-
Differential - Final Drives - Front
49 gal (US)
49.1 gal (US)
-
Differential - Final Drives - Rear
45 gal (US)
49.1 gal (US)
-
Hydraulic System Factory Fill
94 gal (US)
125.5 gal (US)
-
Note
Cat diesel engines are required to use ULSD (ultra-low sulfur diesel fuel with 15 ppm of sulfur or less) and are compatible* with ULSD blended with the following lower-carbon intensity fuels** up to: - 20% biodiesel FAME (fatty acid methyl ester) *** - 10
• All non-road Tier 4 Final/Stage V diesel engines are required to use ULSD (ultra-low sulfur diesel fuel with 15 ppm of sulfur or less) or ULSD blended with the following lower-carbon intensity fuels** up to: – 20% biodiesel FAME (fatty acid methyl ester
-
Coolant (Validated by Test Cell Fill Quantities)
-
33 gal (US)
-
Crankcase
-
15.9 gal (US)
-
Diesel Exhaust Fluid Tank (For Tier 4 Final/Stage V Only)
-
8.7 gal (US)
-
Transmission - Validated by Test Cell Fill Quantities
-
29 gal (US)
-
Hydraulic System - Tank Only
-
63.4 gal (US)
-
Dimensions (Approximate) - High Lift
Ground to Top of ROPS
13.5 ft
-
-
Ground to Top of Exhaust Stacks
13.3 ft
-
-
Ground to Top of Hood
10.7 ft
-
-
Ground to Fuel Tank Clearance
2.2 ft
-
-
Rear Axle - Centerline to Bumper
10.3 ft
-
-
Front Axle Centerline to Bucket Tip
16.7 ft
-
-
Wheel Base
12.5 ft
-
-
Maximum Overall Length
39.5 ft
-
-
Ground to Lower Hitch Clearance
1.5 ft
-
-
Ground to Center of Front Axle
3.2 ft
-
-
Clearance at Maximum Lift (45° Dump)
12 ft
-
-
B-Pin Height - Maximum Lift
18.7 ft
-
-
Maximum Overall Height - Bucket Raised
25 ft
-
-
Reach at Maximum Lift (45° Dump)
7.7 ft
-
-
Note
Specifications are calculated with 6.9 m3 (9.0 yd3 ) rock bucket equipped with Michelin XLDD1 35/65 R33 tires.