Two engine emission options are available: 1. Meets U.S. EPA Tier 4 Final, EU Stage V, and Japan emission standards. 2. Meets Brazil MAR-1 emission standards, equivalent to U.S. EPA Tier 3 and EU Stage IIIA.
-
-
Note (2)
Net power advertised is the power available at the flywheel when the engine is equipped with fan at minimum speed, air intake system, exhaust system, and alternator.
-
-
Note (3)
Net power at the flywheel when the fan is at maximum speed is 304 kW / 408 hp per SAE reference conditions.
-
-
Net Power
-
814 hp
-
Emissions
-
U.S. EPA Tier 4 Final, U.S. EPA Tier 2 Equivalent
-
Gross Power - SAE J1995 at 1,750 rpm - Tier 4/HRC (Highly Regulated Country) - Standard
-
900 hp
-
Gross Power - SAE J1995 at 1,750 rpm - Tier 4/HRC - High Ambient
-
937 hp
-
Gross Power - SAE J1995 at 1,750 rpm - Tier 2/LRC (Less Regulated Country) - Standard
-
907 hp
-
Gross Power - SAE J1995 at 1,750 rpm - Tier 2/LRC - High Ambient
-
944 hp
-
Gross Power - ISO 14396 at 1,750 rpm - Tier 4/HRC - Standard
-
884 hp
-
Gross Power - ISO 14396 at 1,750 rpm - Tier 4/HRC - High Ambient
-
921 hp
-
Gross Power - ISO 14396 at 1,750 rpm - Tier 2/LRC - Standard
-
893 hp
-
Gross Power - ISO 14396 at 1,750 rpm - Tier 2/LRC - High Ambient
-
931 hp
-
Net Power - SAE J1349 at 1,750 rpm - Tier 4/HRC - Standard
-
814 hp
-
Net Power - SAE J1349 at 1,750 rpm - Tier 4/HRC - High Ambient
-
814 hp
-
Net Power - SAE J1349 at 1,750 rpm - Tier 2/LRC - Standard
-
823 hp
-
Net Power - SAE J1349 at 1,750 rpm - Tier 2/LRC - High Ambient
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a or R1234yf. See the label or instruction manual for identification of the gas. - If equipped with R134a (Global Warming Potential = 1430), the system co
-
-
Axles
Front
Fixed
Fixed
-
Rear
Trunnion
Trunnion
-
Oscillation Angle
+/-12.5°
±9°
-
Brakes
Brakes
ISO 3450:2011
ISO 3450:2011
-
Operator's Cab
ROPS/FOPS
Rollover Protective Structure/Falling Objects Protective Structure (ROPS/FOPS) meet ISO 3471:2008 and ISO 3449:2005 Level II standards
-
-
Sound Performance - Tier 4 Final / Stage V
Operator Sound Pressure Level (ISO 6396:2008)
73 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
113 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
72 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)**
110 dB(A)
-
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives.”
-
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701.
-
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Sound Performance - Tier 3 / Stage IIIA
Operator Sound Pressure Level (ISO 6396:2008)
74 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)
113 dB(A)
-
-
Operator Sound Pressure Level (ISO 6396:2008)*
73 dB(A)
-
-
Machine Sound Power Level (ISO 6395:2008)**
110 dB(A)
-
-
Note (1)
* For machines in European Union countries and in countries that adopt the “EU Directives” and “UK Directives.”
-
-
Note (2)
** European Union Directive “2000/14/EC” as amended by “2005/88/EC” and UK Noise Regulation 2001 No. 1701.
-
-
Note (3)
The machine sound power level was measured according to ISO 6395:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level was measured according to ISO 6396:2008. The measurement was conducted at 70% of the maximum engine cooling fan speed.
-
-
Note (5)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Service Refill Capacities
Fuel Tank
141 gal (US)
385.7 gal (US)
-
Cooling System
27 gal (US)
-
-
Engine Crankcase
9 gal (US)
-
-
Diesel Exhaust Fluid Tank
5.5 gal (US)
-
-
Transmission
20 gal (US)
51.5 gal (US)
-
Differential - Final Drives - Front
49 gal (US)
96.4 gal (US)
-
Differential - Final Drives - Rear
45 gal (US)
96.4 gal (US)
-
Hydraulic System Factory Fill
94 gal (US)
-
-
Note
Cat diesel engines are required to use ULSD (ultra-low sulfur diesel fuel with 15 ppm of sulfur or less) and are compatible* with ULSD blended with the following lower-carbon intensity fuels** up to: - 20% biodiesel FAME (fatty acid methyl ester) *** - 10
-
-
Cooling Systems
-
59.4 gal (US)
-
Crankcase
-
31.7 gal (US)
-
Hydraulic System Factory Fill (Implement)
-
104.1 gal (US)
-
Hydraulic Tank - Implement
-
60.2 gal (US)
-
Hydraulic Factory Fill (Steering)
-
32.5 gal (US)
-
Hydraulic Tank (Steering Tank Only)
-
26.3 gal (US)
-
Dimensions (Approximate) - High Lift
Ground to Top of ROPS
13.5 ft
-
-
Ground to Top of Exhaust Stacks
13.3 ft
-
-
Ground to Top of Hood
10.7 ft
-
-
Ground to Fuel Tank Clearance
2.2 ft
-
-
Rear Axle - Centerline to Bumper
10.3 ft
-
-
Front Axle Centerline to Bucket Tip
16.7 ft
-
-
Wheel Base
12.5 ft
-
-
Maximum Overall Length
39.5 ft
-
-
Ground to Lower Hitch Clearance
1.5 ft
-
-
Ground to Center of Front Axle
3.2 ft
-
-
Clearance at Maximum Lift (45° Dump)
12 ft
-
-
B-Pin Height - Maximum Lift
18.7 ft
-
-
Maximum Overall Height - Bucket Raised
25 ft
-
-
Reach at Maximum Lift (45° Dump)
7.7 ft
-
-
Note
Specifications are calculated with 6.9 m3 (9.0 yd3 ) rock bucket equipped with Michelin XLDD1 35/65 R33 tires.
-
-
Buckets
Bucket Capacities
-
11.5-24.5 m³ (15-32 yd³)
-
Cooling System
Ambient Capability Hydraulically Driven Demand Fan - Standard
-
109.4 °F
-
Ambient Capability, Hydraulically Driven Demand Fan - High