CG260-16 Gas Generator Set
Cat Customizable Switchgear and Controls
EMCP 4.4 Master Control Panel

Generator Set Specifications

Continuous Rating 4500 / 4050 ekW @1.0pf - -
Fuel Type Natural Gas, Hydrogen Blend (up to 25%) - -
Maximum Electrical Efficiency 44.60 / 44.3% - -
Maximum Standby Rating 4500 ekW - -
Frequency 50 / 60 Hz - -
RPM 1000 / 900 rpm - -

Generator Set Dimensions

Length 371 in - -
Width 110 in - -
Height 133 in - -
Dry Weight - Genset 117505 lb - -

Engine Specifications

Engine Model CG260-16 - -
Displacement 16586 in³ - -
Stroke 12.6 in - -
Bore 10.2 in - -
Aspiration TA - -

Technical Summary

Configuration - Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.
Modes of Operation - All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow Emergency standby, island, utility paralleling
Application - LV and MV ( 208V - 38 kV) 50 / 60 Hz LV and MV (208V - 38 kV)

Generator Protective Devices

ANSI Protective Devices - Per customer specification 15/25, 27/59, 81 O/U, 32, 40, 50, 51

Utility Protective Devices

ANSI Protective Devices - Per customer specification 15/25. 27/59, 81 O/U, 32,47 (Industrial Grade)

Environmental Parameters

Certifications - Per customer specification IBC, CBC, UBC & OSHPD Certified
Control Panel Enclosure - Per customer specification NEMA 1 wall-mounted construction
Operating Temperature - Per customer specification 0°C to 50°C
Storage Temperature - Per customer specification -20°C to +60°C
Low Voltage Standards - Per customer specification NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70
Medium Voltage Standards - Per customer specification NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110
Add a Similar Product:
  • Cat G3512H Combined Heat and Power (CHP) Solution Add
  • 3516C Tier 4 Final Add
  • 3516C Generator Set Add
  • 3516C (50 Hz) with Upgradeable Package Add
  • G3512 1000kW Gas Generator Set Add
  • Gas Generator G3512H Add
  • 3516C Generator Set Add
  • G3512 750kW Gas Generator Set Add
  • 3516B (60 Hz) with Upgradeable Package Add
  • G3412 Gas Generator Set Add