Compare Equipment Go Back
CG260-16 Gas Generator Set |
Cat Customizable Switchgear and Controls |
Energy Time Shift (ETS) Module |
|
Generator Set Specifications |
|||
---|---|---|---|
Continuous Rating | 4300 / 4000 ekW @1.0pf | - | - |
Fuel Type | Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas, Hydrogen Blend (to 25%) | - | - |
Maximum Electrical Efficiency | 44.1 / 43.8% | - | - |
Maximum Standby Rating | 4500 ekW | - | - |
Frequency | 50 / 60 Hz | - | - |
RPM | 1000 / 900 rpm | - | - |
Engine Specifications |
|||
Engine Model | CG260-16 | - | - |
Displacement | 16586 in³ | - | - |
Aspiration | TA | - | - |
Bore | 10.2 in | - | - |
Stroke | 12.6 in | - | - |
Generator Set Dimensions |
|||
Length | 371 in | - | - |
Width | 110 in | - | - |
Height | 133 in | - | - |
Dry Weight - Genset | 117505 lb | - | - |
Technical Summary |
|||
Configuration | - | Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc | - |
Modes of Operation | - | All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow | - |
Application | - | LV and MV ( 208V - 38 kV) 50 / 60 Hz | Peak Shaving |
Module Type | - | - | Energy Time Shift |
Nameplate Power | - | - | 570 kW | 1000 kW |
Nameplate Energy Capacity | - | - | 1518 kWh |
Generator Protective Devices |
|||
ANSI Protective Devices | - | Per customer specification | - |
Utility Protective Devices |
|||
ANSI Protective Devices | - | Per customer specification | - |
Environmental Parameters |
|||
Certifications | - | Per customer specification | - |
Control Panel Enclosure | - | Per customer specification | - |
Operating Temperature | - | Per customer specification | - |
Storage Temperature | - | Per customer specification | - |
Low Voltage Standards | - | Per customer specification | - |
Medium Voltage Standards | - | Per customer specification | - |
Add a Similar Product:
- Cat XLM Switchgear Add
- Cat Switchgear Add
- EMCP 4.4 Master Control Panel Add
- Cat EGP Switchgear Add
- Engine Paralleling and Integration Control (EPIC) Add
- Energy Capacity Expansion (ECE) module Add
- Cat® BDP1000 Bi-Directional Power Inverter Add
- XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
- Temporary Connection Boxes Add
- XQ425 Add