G3520H Gas Generator |
Engine Paralleling and Integration Control (EPIC) |
Cat Customizable Switchgear and Controls |
|
Generator Set Specifications |
|||
---|---|---|---|
Continuous Rating | 2519 / 2500 ekW @ 1.0pf | - | - |
Fuel Type | Natural Gas, Hydrogen Blend (up to 25%) | - | - |
Maximum Electrical Efficiency | 45.30% | - | - |
Frequency | 50/60 Hz | - | - |
RPM | 1500 | - | - |
Engine Specifications |
|||
Engine Model | G3520H | - | - |
Displacement | 5956 in³ | - | - |
Aspiration | TA | - | - |
Bore | 6.7 in | - | - |
Stroke | 8.5 in | - | - |
Compression Ratio | 12.1 | - | - |
Generator Set Dimensions |
|||
Length | 302 in | - | - |
Width | 86 in | - | - |
Height | 97 in | - | - |
Dry Weight - Genset | 54675 lb | - | - |
Technical Summary |
|||
Configuration | - | Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control) | Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc |
Modes of Operation | - | Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel) | All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow |
Application | - | LV and MV (208V-27kV) | LV and MV ( 208V - 38 kV) 50 / 60 Hz |
Generator Protective Devices |
|||
ANSI Protective Devices | - | 15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade) | Per customer specification |
Utility Protective Devices |
|||
ANSI Protective Devices | - | 15/25. 27/59, 81 O/U, 32,47 (Industrial Grade) | Per customer specification |
Environmental Parameters |
|||
Certifications | - | UL / cUL 508A | Per customer specification |
Control Panel Enclosure | - | NEMA 12 | Per customer specification |
Operating Temperature | - | 0°C to 55°C | Per customer specification |
Storage Temperature | - | -20°C to 60°C | Per customer specification |
Low Voltage Standards | - | - | Per customer specification |
Medium Voltage Standards | - | - | Per customer specification |
Add a Similar Product:
- Cat Switchgear Add
- Cat XLM Switchgear Add
- Cat EGP Switchgear Add
- EMCP 4.4 Master Control Panel Add
- Energy Capacity Expansion (ECE) module Add
- Cat® BDP1000 Bi-Directional Power Inverter Add
- Energy Time Shift (ETS) Module Add
- XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
- Temporary Connection Boxes Add
- XQP550 EU Stage V Add