Compare Equipment Go Back

DG100 (60 Hz)
Cat EGP Switchgear
Cat XLM Switchgear

Generator Set Specifications

Frequency 60 Hz - -
Gas Standby Rating 100 ekW - -
Emissions/Fuel Strategy U.S. EPA Certified for Stationary Emergency Application - -
Speed 1800 rpm - -
Voltage 208-600 - -

Engine Specifications

Engine Model V8, 6.2L TCAC - -
Stroke 3.75 in - -
Displacement 378.3 in³ - -
Compression Ratio 9.8:1 - -
Aspiration TCAC - -
Bore 4 in - -
Fuel System Electronic - -

Generator Set Dimensions

Length 96 in - -
Width 51 in - -
Height 57 in - -
Dry Weight - Genset 3007 lb - -

Technical Summary

Configuration - Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
Modes of Operation - Multi-unit Island and multi-unit standby mode with optional redundant controls and components. Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
Application - LV and MV (208V - 38 kV) LV and MV ( 208V - 38 kV

Generator Protective Devices

ANSI Protective Devices - 15/25, 27/59, 81 O/U, 32, 40, 50, 51 15/25, 27/59, 81 O/U, 32, 40, 50, 51

Environmental Parameters

Certifications - IBC, CBC, UBC & OSHPD Certified IBS, CBC, UBC & OSHPD Certified
Control Panel Enclosure - NEMA 1 or NEMA 3R Freestanding Construction NEMA 1 or NEMA 3R, Freestanding Construction
Operating Temperature - 0°C to 50°C 0 degrees to 50 degrees C
Storage Temperature - -20°C to +60°C -20 degrees C to +60 degrees C
Low Voltage Standards - NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70 NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70
Medium Voltage Standards - NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110 NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110

Utility Protective Devices

ANSI Protective Devices - - 15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86
Add a Similar Product:
  • Cat Switchgear Add
  • Cat Customizable Switchgear and Controls Add
  • Engine Paralleling and Integration Control (EPIC) Add
  • EMCP 4.4 Master Control Panel Add
  • Energy Time Shift (ETS) Module Add
  • Energy Capacity Expansion (ECE) module Add
  • Cat® BDP1000 Bi-Directional Power Inverter Add
  • XQ570 Tier 4 Final – 455 ekW (568 kVA) Add
  • Temporary Connection Boxes Add
  • XQ425 Add