Net power advertised is the power available at the engine flywheel when the engine is equipped with a fan, air cleaner, clean emissions module and alternator.
-
-
Operating Specifications - Tier 4 Final/EU Stage V
Operating Weight
48526 lb
-
-
Scoops
Chip Scoop Doze Capacity
37.9 yd³
-
-
Chip Scoop Carry Capacity
19 yd³
-
-
Engine - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA
Engine Model
Cat C7.1
-
-
Emissions
Brazil MAR-1 and China Nonroad Stage III, equivalent to Tier 3/EU Stage IIIA
-
-
Rated Speed
2200 r/min
-
-
Net Power (SAE J1349:2011)
249 HP
-
-
Gross Power (SAE J1995:2014)
286 HP
-
-
Engine Power (ISO 14396:2002)
275 HP
-
-
Peak Torque - 1,400 rpm
749 lb/ft
-
-
Torque Rise
26%
-
-
Bore
4.1 in
-
-
Stroke
5.3 in
-
-
Displacement
427.8 in³
-
-
High Idle Speed
2270 r/min
-
-
Operating Specifications - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA
Operating Weight
47887 lb
-
-
Operating Specifications - Tier 4 Final/EU Stage V - Scoop
Operating Weight
52280 lb
-
-
Operating Specifications - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA - Scoop
Operating Weight
51639 lb
-
-
Transmission
Transmission Type
Cat Planetary Power Shift
-
-
Forward - 1
3.7 mile/h
-
-
Forward - 2
6.5 mile/h
-
-
Forward - 3
11.2 mile/h
-
-
Forward - 4
19.4 mile/h
-
-
Reverse - 1
4.2 mile/h
-
-
Reverse - 2
7.3 mile/h
-
-
Reverse - 3
12.8 mile/h
-
-
Reverse - 4
22.1 mile/h
-
-
Hydraulic System - Lift/Tilt
Lift/Tilt System - Circuit
Pilot operated LS valve with EH
-
-
Lift/Tilt System
Variable displacement piston
-
-
Maximum Flow at 2,200 rpm
23.5 gal/min
-
-
Relief Valve Setting - Lift/Tilt
3190 psi
-
-
Cylinders, Double Acting - Lift, Bore and Stroke
120 mm × 915 mm (4.7 in × 36.0 in)
-
-
Cylinders, Double Acting - Left and Right Tilt, Bore and Stroke
101.6 mm × 234 mm (4.0 in × 9.2 in)
-
-
Pilot System
Open center, fixed displacement gear
-
-
Pilot Relief Valve Setting
3046 psi
-
-
Hydraulic System - Steering
Steering System - Circuit
Pilot, load sensing
-
-
Steering System - Pump
Variable displacement piston
-
-
Maximum Flow at 2,200 rpm
38.8 gal/min
-
-
Relief Valve Setting - Steering
4003 psi
-
-
Total Steering Angle
72°
-
-
Steering Cycle Times - High Idle
3 s
-
-
Steering Cycle Times - Low Idle
8.2 s
-
-
Service Refill Capacities
Fuel Tank
132.1 gal (US)
-
-
Diesel Exhaust Fluid Tank
4.2 gal (US)
-
-
Cooling Systems - Tier 4 Final/EU Stage V
21.4 gal (US)
-
-
Cooling Systems - Brazil MAR-1 and China NonroadStage III, equivalent to Tier 3/EU Stage IIIA
19.3 gal (US)
-
-
Engine Crankcase
5.3 gal (US)
-
-
Transmission
13.2 gal (US)
-
-
Differential - Final Drives - Front
17.2 gal (US)
-
-
Differential - Final Drives - Rear
17.2 gal (US)
-
-
Hydraulic System - Implement/Steering
34.1 gal (US)
-
-
Hydraulic Tank Only
19.8 gal (US)
-
-
Axles
Front
Planetary – Fixed
-
-
Rear
Planetary – Oscillating
-
-
Oscillation Angle
±10°
-
-
Braking System
Service Brakes
Single Disc Wet (enclosed) 4 WHL
-
-
Parking Brake
Drum and Shoe, Spring Applied, Hydraulic Released
-
-
Dimensions (Approximate)
Height to Top of Beacon
13.1 ft
-
-
Height - Top of Cab
12.1 ft
-
-
Height - Top of Exhaust Pipe
11.3 ft
-
-
Height - Top of Hood
8.7 ft
-
-
Height to Top of Radiator Guard
8 ft
-
-
Ground Clearance to Hitch
1.4 ft
-
-
Ground Clearance to Transmission Guard
1.4 ft
-
-
Ground Clearance to Bottom of Bumper
2.3 ft
-
-
Centerline of Rear Axle to Bumper
6.5 ft
-
-
Centerline of Front Axle to Hitch
5.5 ft
-
-
Wheel Base
11 ft
-
-
Width over Platform
10.3 ft
-
-
Overall Length to Front Tire
21 ft
-
-
Overall Machine Length with Straight Blade
23.6 ft
-
-
Overall Machine Length with Coal Blade
25.5 ft
-
-
Sound Performance - Tier 4 Final/EU Stage V - Standard
Operator Sound Level (ISO 6396)
70 dB(A)
-
-
Machine Sound Level (ISO 6395)
111 dB(A)
-
-
Note (1)
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
-
Note (2)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Note (3)
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level uncertainty is ± 2 dB(A)
-
-
Sound Performance - Tier 4 Final/EU Stage V - Suppression
Operator Sound Level (ISO 6396)
70 dB(A)
-
-
Machine Sound Level (ISO 6395)
109 dB(A)
-
-
Note (1)
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
-
Note (2)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Note (3)
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level uncertainty is ± 2 dB(A).
-
-
Sound Performance - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA - Standard
Operator Sound Level (ISO 6396)
70 dB(A)
-
-
Machine Sound Level (ISO 6395)
112 dB(A)
-
-
Note (1)
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
-
Note (2)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Note (3)
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level uncertainty is ± 2 dB(A).
-
-
Sound Performance - Brazil Mar-1 and China Nonroad Stage III, Equivalent to Tier 3/EU Stage IIIA - Suppression
Operator Sound Level (ISO 6396)
70 dB(A)
-
-
Machine Sound Level (ISO 6395)
110 dB(A)
-
-
Note (1)
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
-
Note (2)
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment.
-
-
Note (3)
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed.
-
-
Note (4)
The operator sound pressure level uncertainty is ± 2 dB(A).