Adequate warm up and cool down time is just one vital step in eliminating undue stress on your components - something that can lead to costly, premature machine failure. After performing your daily safety inspection, we recommend you follow these start up and shut down practices to minimize undue component wear and damage.

MACHINE START UP

  • Allow machine to warm up per OMM
  • Engage and disengage attachment controls to help speed warm-up of hydraulic components
  • Cycle all controls to allow warm oil to circulate through all hydraulic cylinders and lines
  • Perform steering, service brake, and parking brake operation checks (per OMM by machine model)
  • Check secondary steering operation (if equipped)
  • Check gauges, indicators, and action light frequently

MACHINE SHUT DOWN

  • Park the machine on smooth level area
  • Set parking brake
  • Lower all hydraulic implements
  • Run engine at low idle for five (5) minutes to allow engine to cool
  • Turn key start switch to OFF and remove key
  • Dismount machine using 3-point contact
  • Block wheels and remove disconnect switch key if parking for extended period (per OMM)
  • Drain water from air tank, if equipped
  • Conduct post-operation walk-around inspection